How to Choose a Battery for AGV and AMR Robots: Key Technical Requirements

How to Choose a Battery for AGV and AMR Robots: Key Technical Requirements

  • Categories:Blog
  • Author:
  • Origin:
  • Time of issue:2026-11-06
  • Views:0

(Summary description)Learn how to choose the right AGV and AMR battery. Explore voltage, capacity, runtime, discharge current, fast charging, CAN bus, RS485, BMS protection and custom battery design.

How to Choose a Battery for AGV and AMR Robots: Key Technical Requirements

(Summary description)Learn how to choose the right AGV and AMR battery. Explore voltage, capacity, runtime, discharge current, fast charging, CAN bus, RS485, BMS protection and custom battery design.

  • Categories:Blog
  • Author:
  • Origin:
  • Time of issue:2026-11-06
  • Views:0
Information

 

Automated Guided Vehicles (AGVs) and Autonomous Mobile Robots (AMRs) are becoming essential parts of modern warehouses, manufacturing facilities, distribution centres, and automated logistics systems. As these robots take on more demanding tasks, their battery systems must deliver reliable power, sufficient operating time, fast charging capability, and stable communication with the vehicle control system.

 

However, choosing an AGV or AMR battery is not simply a matter of selecting the correct voltage or the largest amp-hour capacity. A battery that works well in a conventional electric vehicle may not be suitable for an industrial mobile robot. AGVs and AMRs often operate for long shifts, accelerate frequently, carry different payloads, use multiple sensors, and return to charging stations at scheduled intervals.

 

At MICA POWER, we approach robot battery selection from a complete application perspective. We consider the electrical load, operating schedule, charging strategy, communication requirements, installation space, and safety functions before recommending a battery configuration.

 

This guide explains eight key technical requirements that equipment manufacturers, automation integrators, and procurement teams should evaluate when choosing a battery for AGV and AMR robots.

 

 

 

1. What is an AGV/AMR Battery?

 

An AGV/AMR battery is a rechargeable power source designed to supply the traction system, control electronics, sensors, and auxiliary equipment of an automated mobile robot.

Unlike a battery used in a simple portable device, an industrial robot battery must support a defined operating cycle. It may need to deliver power during acceleration, maintain stable output while carrying loads, support electronic systems during standby, and recharge during short breaks.

 

AGV vs. AMR: Do They Need Different Batteries?

AGVs and AMRs are both mobile automation platforms, but their navigation and operating methods can differ.

  • AGV (Automated Guided Vehicle): Typically follows predefined routes using guidance systems such as magnetic tape, QR codes, reflectors, or other navigation infrastructure.

  • AMR (Autonomous Mobile Robot): Uses onboard sensing and navigation technology to understand its surroundings and select routes dynamically.

Their battery requirements are not determined by the navigation method alone. Payload, motor power, travel distance, acceleration, auxiliary electronics, and charging schedules are often more important.

 

Application Typical Battery Considerations
Warehouse AGV Long operating hours, repetitive routes, reliable charging
Warehouse AMR Variable travel routes, sensors, computers, frequent charging
Industrial transport robot High discharge current, heavy payload, vibration resistance
Pallet-moving AGV Traction and lifting loads, peak current capability
Cleaning robot Long runtime, auxiliary motor loads, charging automation
Mobile manipulator Traction power plus robotic arm and control-system loads

 

Why is LiFePO4 Commonly Considered?

 

Lithium iron phosphate (LiFePO4 or LFP) is a popular option for industrial battery applications because it combines relatively stable voltage performance, thermal stability, and good cycle-life potential.

 

For AGV and AMR applications, LiFePO4 can offer several practical advantages:

 

  • Supports repeated charge and discharge cycles.

  • Provides relatively stable voltage during much of the discharge process.

  • Can be configured for high-current discharge.

  • Supports partial charging when the selected cells and BMS permit it.

  • Requires no routine electrolyte maintenance.

  • Can be integrated with smart BMS monitoring and communication functions.

 

However, not every LiFePO4 battery is suitable for an AGV. The cell specification, pack structure, BMS current rating, charging limits, and communication protocol must all match the robot's requirements.

 

 

2. Key Battery Requirements for AGV and AMR Robots

 

Before selecting a battery model, we recommend reviewing the robot's complete electrical and mechanical requirements.

A suitable battery should meet the following specifications.

 

2.1 Voltage Compatibility

Battery voltage must match the operating range of the robot's motor controller, DC/DC converters, onboard computers, and other electrical components.

Common voltage classes for mobile robots include 12V, 24V, 36V, 48V, and higher-voltage configurations. The appropriate choice depends on the vehicle architecture and power requirements.

 

For example, an 8-series LiFePO4 battery has a nominal voltage of:

8 × 3.2V = 25.6V.

Its typical maximum charging voltage at 3.65V per cell is:

8 × 3.65V = 29.2V.

Therefore, a battery described as a 24V-class LiFePO4 battery may have a nominal voltage of 25.6V and a higher full-charge voltage.

We always recommend checking the controller's minimum and maximum input voltage rather than matching the battery based only on its product label.

 

2.2 Capacity and Operating Time

Battery capacity is usually expressed in amp-hours (Ah), while energy is expressed in watt-hours (Wh) or kilowatt-hours (kWh).

A robot operating for an entire shift may require a larger battery than one that returns to a charging station several times per day.

 

Capacity selection should account for:

 

  • Average power consumption.

  • Required operating hours.

  • Traction motor energy consumption.

  • Lifting and auxiliary equipment.

  • Charging opportunities.

  • Battery aging and operating reserves.

 

2.3 Discharge Performance

AGVs and AMRs frequently experience changes in current demand.

A robot may draw moderate current while moving at a steady speed but require significantly higher current during acceleration, climbing, turning, or lifting.

The battery cells, BMS, cables, connectors, and protection devices must all support the required current.

 

2.4 Cycle Life and Operating Availability

Industrial robots may operate across multiple shifts. Frequent charging and discharging can result in a high number of battery cycles.

For this reason, battery selection should consider the expected daily energy throughput, depth of discharge, charging temperature, and required service life.

A battery that meets the runtime requirement when new may not provide sufficient runtime after years of operation if its aging allowance was not considered during design.

 

2.5 Mechanical and Environmental Requirements

The battery must fit the robot's installation space and operate within the specified environmental conditions.

Important considerations include:

 

  • Maximum battery length, width, and height.

  • Weight limitations.

  • Mounting and vibration resistance.

  • Connector type and cable routing.

  • Operating temperature.

  • Dust and moisture exposure.

  • Enclosure protection requirements.

 

These factors are particularly important for compact AMRs, where battery space may be limited by sensors, drive systems, and onboard computers.

 

 

3. How to Calculate Required Battery Capacity and Runtime

 

Battery capacity calculation is one of the most important steps in AGV and AMR battery selection.

A common mistake is to calculate capacity using only the motor's rated power. In reality, a mobile robot's total energy consumption includes traction, control systems, sensors, lifting equipment, and other auxiliary loads.

 

Step 1: Calculate Average Power Consumption

Start by identifying the power consumption of the main electrical components.

Component Typical Power Consumption Consideration
Drive motors Depends on vehicle weight, speed, acceleration, and terrain
Navigation sensors Depends on sensor type and operating mode
Industrial computer Continuous electrical load during operation
Control system Usually operates throughout the working cycle
Lifting mechanism Intermittent high-power load
Communication equipment Continuous or intermittent load
Auxiliary equipment Depends on robot configuration

 

Where possible, measure actual battery-side energy consumption over a representative operating cycle. This is more useful than simply adding the maximum rated power of every component.

For example, a robot may not operate its lifting mechanism continuously. Using its maximum power for the entire shift would overestimate average consumption.

 

Step 2: Calculate Energy Requirements

The basic formula is:

Required Energy (Wh) = Average Power (W) × Operating Time (h)

Suppose an AMR has an average power consumption of 500W and must operate for eight hours between charging periods.

Required energy:

500W × 8h = 4,000Wh = 4kWh.

This is the estimated energy required by the robot during that operating period. It is not yet the nominal battery capacity.

 

Step 3: Include Usable Capacity and Design Margin

The battery should not necessarily be discharged to its absolute lower limit during normal operation.

For an illustrative LiFePO4 sizing calculation, assume:

  • Required operating energy: 4kWh.

  • Planned usable depth of discharge: 80%.

  • Additional design allowance: 20%.

The estimated nominal battery energy is:

4kWh ÷ 0.80 × 1.20 = 6kWh.

This is an initial sizing estimate. The 20% allowance is a design assumption, not a universal standard. Actual sizing should also consider end-of-life capacity, temperature, load variation, and the manufacturer's recommended operating limits.

 

Step 4: Convert Energy into Amp-Hours

Once nominal energy is estimated, calculate the required battery capacity:

Capacity (Ah) = Energy (Wh) ÷ Nominal Voltage (V)

For a 25.6V LiFePO4 system:

6,000Wh ÷ 25.6V ≈ 234.4Ah.

Therefore, a battery configuration around 25.6V 240Ah could be a preliminary candidate, subject to current, space, charging, and system compatibility checks.

 

Example Battery Capacity Calculations

 

Nominal Voltage Capacity Nominal Energy
25.6V 30Ah 768Wh
25.6V 80Ah 2,048Wh
25.6V 100Ah 2,560Wh
48V 50Ah 2,400Wh
51.2V 100Ah 5,120Wh

These values are calculated from nominal voltage multiplied by rated capacity. Actual usable energy depends on discharge limits, temperature, current, battery condition, and system efficiency.

 

How to Estimate Runtime

A simplified runtime formula is:

Estimated Runtime (h) = Usable Battery Energy (Wh) ÷ Average Load (W)

For example, if a 25.6V 80Ah battery stores 2,048Wh nominal energy and the design allows 80% of that energy to be used:

Usable energy = 2,048Wh × 80% = 1,638.4Wh.

At an average load of 300W:

1,638.4Wh ÷ 300W ≈ 5.46 hours.

This is a theoretical estimate, not a guaranteed operating time. Actual runtime may be shorter because of acceleration, payload changes, temperature, conversion losses, and battery aging.

 

 

4. Continuous vs. Peak Discharge Current

 

Battery capacity determines how much energy is available. Discharge current determines how quickly the battery can deliver that energy.

For AGV and AMR robots, both continuous and peak discharge current must be evaluated.

 

What is Continuous Discharge Current?

Continuous discharge current is the maximum current that a battery can supply over a sustained period under the specified operating conditions.

For example, if a 25.6V battery has a continuous discharge rating of 120A, its approximate nominal electrical output at that current is:

25.6V × 120A = 3,072W, or 3.072kW.

The actual output depends on voltage under load, cell temperature, BMS limits, and other electrical components.

 

What is Peak Discharge Current?

Peak discharge current is the higher current a battery can supply for a limited period.

AGVs and AMRs may require short bursts of high current during:

  • Motor startup.

  • Rapid acceleration.

  • Uphill movement.

  • Heavy-load transportation.

  • Lifting operations.

  • Sudden changes in direction.

A battery may therefore have a continuous current rating and a separate peak current rating with a specified duration.

 

Real MICA POWER Product Example

MICA POWER publishes a 25.6V 80Ah LiFePO4 battery for AGV and electric forklift trolley applications.

Its listed specifications include:

Parameter Published Specification
Nominal voltage 25.6V
Nominal capacity 80Ah
Nominal energy 2,048Wh
Continuous discharge current 120A
Burst discharge current 400A for 3 seconds
Discharge cutoff voltage 20V
Maximum charging voltage 29.2V
Weight 20kg
Protection rating IP65
Connector Anderson plug
Charging temperature 0°C to 45°C
Discharging temperature -20°C to 60°C

These are published specifications for this particular product, not a universal AGV battery specification. A project must still confirm whether its current, voltage, runtime, dimensions, and charging requirements are compatible with the selected model.

 

Why BMS Current Ratings Matter

Even if battery cells can deliver high current, the BMS may impose a lower discharge limit.

The complete current path must be evaluated, including:

  • Battery cells.

  • BMS power components.

  • Busbars and internal connections.

  • Cables and connectors.

  • Fuses or circuit breakers.

  • Motor controller input requirements.

We also recommend checking regenerative braking current. When a robot slows down, its motor controller may return energy to the battery. The battery and BMS must be capable of accepting the resulting charging current within their permitted limits.

 

 

5. Opportunity Charging and Fast Charging

 

Charging strategy has a direct impact on AGV and AMR battery capacity requirements.

Some robots return to a charging station only after completing a shift. Others recharge automatically whenever they have a short break between tasks.

This second method is known as opportunity charging.

 

What Is Opportunity Charging?

Opportunity charging means charging a battery during short periods when the robot is not performing its main task.

For example, an AMR may return to a charging station during:

  • Waiting periods between assignments.

  • Loading and unloading.

  • Scheduled breaks.

  • Shift changes.

  • Idle periods in the production process.

Instead of relying entirely on one long charging session, the robot receives multiple partial charges throughout the working day.

 

Benefits of Opportunity Charging

A suitable opportunity-charging strategy can:

  • Reduce the need for very large battery capacity.

  • Help maintain battery state of charge during long operating schedules.

  • Reduce long charging interruptions.

  • Support higher equipment availability.

  • Improve fleet scheduling flexibility.

However, opportunity charging is not automatically suitable for every lithium battery.

The selected cells must support the required charging current and frequency. The BMS must allow the charging profile, and the charging station must provide compatible voltage, current, and communication.

 

What Should Be Checked Before Fast Charging?

 

Parameter Why It Matters
Maximum charge current Must remain within cell and BMS limits
Charging voltage Must match the battery configuration
Cell temperature Charging must remain within permitted temperature limits
Charging frequency Must be compatible with the expected duty cycle
Connector rating Must safely support the charging current
Charger communication May be required for coordinated charging
Charge termination Must follow the battery manufacturer's charging profile

For example, a 1C charging rate means a current equal to the battery's rated capacity in amp-hours. For an 80Ah battery, 1C corresponds to 80A.

This is a calculation, not a statement that every 80Ah battery can safely accept 80A charging current. The actual maximum charge current must come from the battery datasheet and BMS specification.

At MICA POWER, charging requirements should be considered during the battery design stage, particularly for robots that rely on automatic docking and frequent partial charging.

 

 

6. CAN Bus and RS485 Communication

 

Modern AGV and AMR battery systems often need to communicate with the robot controller, charger, or fleet management system.

This is why communication interfaces such as CAN bus and RS485 are important considerations when selecting a smart battery pack.

 

What Is CAN Bus Communication?

CAN (Controller Area Network) is a communication bus widely used in industrial and automotive control systems.

In an AGV battery system, CAN communication may allow the BMS to transmit information such as:

  • Battery voltage.

  • Battery current.

  • State of Charge (SoC).

  • Battery temperature.

  • Charging and discharging status.

  • Fault and protection information.

  • Available charging or discharging current limits.

The robot controller can use this information to manage operation, issue low-battery warnings, schedule charging, or respond to battery faults.

 

What Is RS485 Communication?

RS485 is a differential electrical communication standard commonly used in industrial environments.

It can support communication between a BMS and external devices such as controllers, monitoring systems, or charging equipment.

Depending on the system design, RS485 may use protocols such as Modbus RTU.

 

CAN Bus vs. RS485

Comparison CAN Bus RS485
Communication type Differential bus Differential serial interface
Common applications Vehicle and machine control Industrial monitoring and automation
Network structure Multi-node bus Commonly point-to-point or multidrop
Protocol Requires an agreed CAN protocol Often uses Modbus RTU or a custom protocol
Typical battery information SoC, voltage, current, alarms, limits Monitoring data, status, parameters
Integration requirement Matching message IDs and data definitions Matching baud rate, addressing, and data protocol

 

An important point: having a CAN or RS485 port does not automatically guarantee compatibility with an AGV controller.

The battery supplier and robot manufacturer must agree on the communication protocol, data format, baud rate, message definitions, connector pinout, and fault-handling logic.

 

For example, two devices may both support CAN bus but use different message IDs and data structures. They may therefore be unable to exchange useful battery information without protocol adaptation.

Before ordering, we recommend requesting the BMS communication protocol document and testing the connection with the actual robot controller and charger.

 

 

7. Battery Safety and BMS Protection

 

Battery safety is essential in industrial automation because AGVs and AMRs often operate around workers, equipment, inventory, and automated production lines.

A properly designed Battery Management System (BMS) helps monitor battery conditions and protect the cells during charging and discharging.

 

Essential BMS Protection Functions

Overcharge protection

Prevents individual cells from exceeding their permitted charging voltage.

Over-discharge protection

Disconnects the battery when cell voltage reaches the specified lower operating limit.

Overcurrent protection

Helps protect the battery against excessive charging or discharging current.

Short-circuit protection

Responds to abnormal short-circuit conditions to reduce electrical damage and safety risks.

Over-temperature protection

Monitors cell or battery temperature and helps prevent operation outside the specified temperature range.

Low-temperature charging protection

Prevents charging when cell temperature is below the battery manufacturer's permitted charging range, if supported by the BMS.

Cell balancing

Helps maintain more consistent voltage among cells connected in series.

 

Why Temperature Monitoring Matters

Battery performance is affected by temperature.

Low temperatures can reduce available discharge performance and increase internal resistance. Charging below the permitted cell temperature can cause lithium plating in lithium-ion cells, which may create long-term degradation and safety concerns.

 

High temperatures can accelerate battery aging and may trigger BMS protection.

For AGV applications in cold storage, outdoor logistics areas, or hot industrial facilities, the battery operating temperature range should be checked carefully.

 

What Should a Smart BMS Monitor?

Monitoring Item Application Value
Total battery voltage Indicates overall pack voltage
Individual cell voltage Helps identify cell imbalance
Charge and discharge current Supports load and charging management
Battery temperature Helps monitor operating conditions
State of Charge (SoC) Helps estimate remaining operating energy
State of Health (SoH) Helps evaluate battery condition
Fault status Supports alarms and troubleshooting
Communication status Helps verify controller and BMS connectivity

For robots operating across multiple shifts, battery monitoring can also help maintenance teams identify abnormal temperature, repeated protection events, or declining capacity before these issues cause unexpected downtime.

 

 

8. Custom AGV Battery Pack Design

 

A standard battery may be sufficient for some AGV and AMR projects. However, industrial robots often have specific requirements for size, current, charging, communication, and mechanical integration.

In these situations, a customized battery pack can provide a better fit.

At MICA POWER, we approach customized battery development by evaluating the complete application rather than starting with a standard battery model and attempting to adapt the robot around it.

 

Key Elements of Custom AGV Battery Design

1. Cell selection

Cell chemistry, capacity, discharge capability, charging characteristics, and expected cycle life should match the robot's operating profile.

LiFePO4 is often considered when cycle-life potential and thermal stability are important. Other lithium-ion chemistries may be evaluated when energy density or weight is a higher priority.

2. Series and parallel configuration

Series connections determine pack voltage, while parallel connections increase capacity and current capability.

For example:

Configuration Nominal Voltage Capacity
8S1P LiFePO4, 30Ah cells 25.6V 30Ah
8S2P LiFePO4, 30Ah cells 25.6V 60Ah
8S3P LiFePO4, 30Ah cells 25.6V 90Ah

These are illustrative configurations using 3.2V nominal LiFePO4 cells. Actual pack design also depends on cell specifications, current requirements, thermal management, and BMS architecture.

3. BMS customization

The BMS can be selected or configured according to required continuous current, peak current, charging current, protection thresholds, and communication functions.

4. Mechanical structure

The enclosure should match the available installation space and provide suitable protection against vibration, impact, dust, and moisture.

5. Connector and wiring design

Power connectors, communication connectors, terminal positions, cable length, and polarity must be agreed with the robot manufacturer.

6. Communication integration

CAN, RS485, or other interfaces should be selected according to the controller and charger requirements. Protocol testing should be included in the development process.

7. Testing and validation

Before mass production, the battery should be evaluated against the agreed specification. Relevant checks may include:

  • Capacity testing.

  • Charge and discharge performance.

  • Continuous and peak current testing.

  • BMS protection testing.

  • Temperature monitoring.

  • Communication testing.

  • Mechanical and installation checks.

  • Application-level runtime validation.

The exact test plan should reflect the battery design, intended market, and applicable safety and transport requirements.

 

What Information Should You Provide to a Battery Manufacturer?

To make the design process more efficient, prepare the following project information before requesting a quotation.

Required Information Example or Description
Application AGV, AMR, forklift robot, cleaning robot
Nominal voltage 24V, 36V, 48V, or custom
Required capacity Ah or kWh
Average power Measured average battery-side power
Continuous current Maximum sustained discharge current
Peak current Peak value and duration
Runtime Required hours between charging periods
Charging method Standard charging, opportunity charging, or fast charging
Charger Model, voltage, current, and communication
Communication CAN, RS485, or other required interface
Dimensions Maximum length, width, and height
Weight Maximum permitted battery weight
Environment Temperature, humidity, dust, and vibration
Project quantity Prototype, pilot production, or mass production

 

MICA POWER AGV and AMR Battery Solutions

MICA POWER develops customized lithium battery solutions for industrial equipment, AGVs, robotics, and other applications. Our published product range includes a 25.6V 80Ah LiFePO4 battery designed for AGV and electric forklift trolley applications.

We also offer customized battery-pack solutions that can be evaluated according to project requirements, including:

  • Voltage and capacity.

  • Cell configuration.

  • Continuous and peak discharge current.

  • Battery enclosure dimensions.

  • Connector and wiring arrangements.

  • BMS protection functions.

  • CAN or RS485 communication requirements.

  • Charging and monitoring requirements.

Our company was founded in 2009 and provides battery solutions covering cell, BMS, module, and system integration. For AGV and AMR manufacturers, this integrated approach helps bring electrical, mechanical, and control-system requirements into the battery design discussion at an early stage.

Explore our customized battery pack solutions or view the 25.6V 80Ah LiFePO4 battery for AGV applications.

 

 

Frequently Asked Questions About AGV and AMR Batteries

 

1. What type of battery is best for AGV and AMR robots?

LiFePO4 batteries are commonly considered for AGV and AMR applications because of their thermal stability, cycle-life potential, and ability to support repeated charging. The best chemistry depends on the robot's energy requirements, weight limitations, operating conditions, and charging strategy.

 

2. What voltage is commonly used for AGV batteries?

Common AGV battery voltage classes include 24V, 36V, and 48V, although higher-voltage systems are also used. The correct voltage must match the motor controller, DC/DC converters, charger, and other electrical components.

 

3. How do I calculate the required AGV battery capacity?

Multiply the robot's average power consumption in watts by the required operating time in hours to estimate energy consumption in watt-hours. Then account for usable depth of discharge, design margin, battery aging, and operating conditions before converting the required energy into amp-hours.

 

4. What is the difference between continuous and peak discharge current?

Continuous discharge current is the current a battery can supply over a sustained period under specified conditions. Peak discharge current is a higher current that can be supplied temporarily for a defined duration, such as during acceleration or lifting.

 

5. Can AGV batteries support opportunity charging?

Yes, if the selected battery cells, BMS, and charging system support the required charging current and frequency. Opportunity charging allows robots to recharge during short idle periods, helping reduce long charging interruptions.

 

6. Should an AGV battery support CAN bus or RS485?

The required interface depends on the robot controller, charger, and monitoring system. CAN bus and RS485 are both used in industrial battery communication, but the actual protocol, data format, and connector configuration must be compatible.

 

7. What BMS protection functions are important for AGV batteries?

Important functions include overcharge, over-discharge, overcurrent, short-circuit, and temperature protection. Cell balancing, SoC monitoring, fault reporting, and communication functions may also be required.

 

8. Can MICA POWER customize batteries for AGV and AMR robots?

Yes. MICA POWER provides customized battery solutions for AGV and robotics applications. Projects can be evaluated for voltage, capacity, current, enclosure dimensions, connectors, BMS functions, and communication requirements.

 

 

Final Thoughts

 

Choosing the right battery for AGV and AMR robots requires more than matching voltage and capacity. The battery must support the robot's complete operating profile, including average energy consumption, acceleration peaks, charging opportunities, communication, environmental conditions, and installation limitations.

 

We recommend beginning with actual operating data, then evaluating battery voltage, usable energy, continuous and peak current, charging requirements, and BMS protection. For projects with specific mechanical or communication requirements, a customized battery pack may be the most practical solution.

 

At MICA POWER, we believe reliable robot battery performance starts with understanding the application. By considering the battery cells, BMS, enclosure, charging system, and robot controller as one integrated system, we help customers develop battery solutions for dependable industrial automation.

Keyword:

Scan the QR code to read on your phone

Online Support
Customer service hotline
+86-755-2101-2250 +86-755-2101-2250
Service time:
8:00 - 24:00
Customer service group:
MICAService
Customer service group:
Online Support

MICA POWER CO.,LTD

Tel:0769-82677106
Fax:0769-82678809
Phone:(+86)1392291 8702
E-mail:pub@micapower.com

ax

QR code

Copyright © 2020 MICA POWER CO.,LTD.All Rights Reserved   粤ICP备20041866号-2   300.cn

搜索
Search